Contents Chapter 1: Introduction 2: Simple Diode Circuits 3: Simple SCR Circuits 4: Fully Controlled 1 PH 5: Fully Controlled 3 PH 6: Semi - Controlled Rectifier Circuits 7: Switch MOde PowerSupply previous page Section Contents next page

 

Chapter 5
Fully Controlled 3 PH SCR Bridge Rectifier

Section 3
Operation with an RL Load

 

 

Circuit Operation

The circuit of the three-phase fully-controlled bridge rectifier circuit with an RL load and a voltage source has been shown above. The purpose of providing a dc source in the dc link is to illustrate how two-quadrant operation can take place. When the firing angle is held between 0o and 90o, the circuit operates in the rectifier region. When the firing angle is held between 90o and 180o, the circuit can operate in the inverter region if the source E is sufficiently negative. In the inverter region, the power flow is from the dc link to the ac 3-phase source. The inductor reduces the ripple in dc link current.

 

 
TO THE TOP